Standard Features
- 1/16,000 displayed resolution (Max 1/60,000 depending on load cell quality & performace). Internal Resolution 1,000,000,A/D Conversion rate 120 times/ Sec.
- Watchdog virtually eliminates malfunctions that associated with computerized equipment or software failure.
- Full Digital Calibration makes setting ZERO and SPAN Calibration an easy task.
- Drines up to 8 parallel connecting load cells.
- 8k bytes SRAM with Lo-battery backup. Information will not disappear even power failure.
- The settings of function and weighing parameters are all stored in the EEPROM,with storage duration over 40 years.
- Important values and parameters can have storage backup.
- Users can adjust the intensity of digits f ilter to avoid mechanical vibrat ion thatcaused by external environments to achieve high-speed and accuratemeasurement.
- Set point codes can store up to 100 sets of : Final, SP1, SP2, Free Fall, HI, LO.
- Automatic Free Fall Compensat ion provides closer tolerance and preciseweighing.
- 8 Set of control Input: ZERO Input, TARE Input, Tare reset, Startbatch,Abort batch, Print Accumulator, Print Input, Clear, ACC. &COUNT.
- 8 Set of control Output:ZERO Band output, SP1 output, SP2 Output, (Final-FreeFall) output, HI output, LO output, Final Output, MD/Error output.
- Standard Serial Output (20mA Current Loop) for remote display.
- Optional pr inter inter face can automatically print or output data includes: date,time, set point code, serial number, weight, and unit.
As a electronic weighing scale manufacturer, we are committed to delivering reliable weighing solutions tailored to meet diverse industrial needs.
Options | ||
OP-01 Control I/O | ||
OP-02 RS-232 / 422 / 485 | ||
OP-03 Printer Interface | ||
OP-04 BCD | ||
OP-05 Analog 4-20mA | ||
OP-06 Analog 0-10V | ||
OP-07 Remote Set Point Unit:Final Weight | ||
OP-08 RELAY Comtrol Interface |
General
Type | BDI-2006 |
Power Requirements | AC 110V or AC 220±10%,50 / 60Hz, Approx. 17VA |
Net weight | Approx. 3.2kg【7.054lbs】 |
Operation Temperature | -10℃ ~ 45℃ |
Maximum Humidity | 85%【non-condensing】 |
Physical Dimensions | 240 × 190 × 104mm (D × W × H) |
Analog Input and A/D Conversion
Type | BDI-2006 |
Input Sensitivity | ≧0.3uV/D |
ZERO Adjustment Range | 0~20mV |
Load Cell Excitation | DC 10V±1%,230mA, Remote Sensing. Cannected up to 8 350Ω Load Cells. |
Non-Linearity | 0.01% F.S. |
A/D Conversion Method | ΔΣ |
A/D Resolution | ≒1/1,000,000 |
A/D Conversion Rate | Approx. 120Times/Sec. |
Max. Load Cell Input Voltage | 32mV |
ZERO Temperature Comp | ±(0.2uV+0.001% of Dead Load) / ℃ typ |
SPAN Temperature Comp | ± 0.001% ℃ typ |
Max. Resolution | 1/16,000 (BDI-2006 Resolution can reach 1/60,000 depending on load cell quality & performance) |