Weighing indicator wiring: 4-wire and 6-wire load cells
A load cell has two excitation wires, two signal wires and usually a shield. Six-wire cells add two sense wires. Wiring them correctly to the weighing indicator is the first step to a stable reading.
What each wire does
| Terminal | Function |
|---|---|
| EXC+ / EXC- | Excitation voltage supplied by the indicator |
| SIG+ / SIG- | Millivolt output from the load cell |
| SEN+ / SEN- | Sense lines that measure the excitation voltage at the cell (6-wire) |
| Shield | Drain for electrical noise, grounded at one point |
4-wire or 6-wire
Six-wire connection lets the indicator compensate for voltage drop along long cables and for cable temperature changes. With a 4-wire load cell on a 6-wire indicator, link SEN+ to EXC+ and SEN- to EXC- at the indicator terminal. Wire colors differ between brands, so always follow the load cell data sheet.
Several load cells
Connect each load cell to a junction box and run one cable to the indicator. The junction box is also where corner errors are trimmed. Check the indicator's limit on the number of load cells; BDI-9301B and BDI-2001B take up to 8.
Keep the signal clean
- Route load cell cables away from motor, inverter and power cables.
- Ground the shield at the indicator end only, to avoid ground loops.
- Use sealed junction boxes outdoors and surge protection on weighbridges.
More weighing FAQ
Tell us what you weigh, the capacity, accuracy and where it will be used.