BDI-9301B Weighing Indicator & Controller

Type:BDI-9301B
It supports MODBUS communication.
A/D 40 times/sec. Max. Div. 1/15,000.
For One material code Filling machine, Hopper scale, etc.
For Platform scale up to 8 Load Cells.

Production information

Standard Features

  • Watchdog virtually eliminates malfunctions that associated with computerized equipmentor software failure. Full Digital Calibration makes setting ZERO and SPAN Calibrationan easy task.
  • The weighing indicator controller fully digital calibration with adjustment, therefore improve the convenience of instrumentinstallation.
  • Drives up to 8 parallel connecting load cells, suitable for large truck scales.
  • 1/15,000 displayed resolution, A/D conversion rate 40 times/ Sec.
  • FLASH MEMORY will ensure data in case of power failure.
  • The settings of function and weighing parameters are all stored in the EEPROM, with storageduration over 40 years.
  • Users can adjust the intensity of digits filter to avoid mechanical that caused by externalenvironments to achieve high-speed and accurate measurement.
  • 8 modes of control applications.
  • Standard RS232 Output.
  • Standard Serial Output (20mA Current Loop) for remote display.
  • The BDI-9301B can be automatically printed or transmit data via function settings withoutmanual operation.

 

 
Options
OP-01 Control I/O
OP-02 RS-422/485 MODBUS RTU
OP-04 BCD
OP-05 Analog 4-20mA or 0-10V
OP-08 RELAY Control Interface (Added on OP-01)
 

General

General
Type BDI-9301B
Power Requirement AC 110V±10% or AC 220V±10%,50/60Hz, Approx 17VA
Net weight Approx 2.45 kg (5.39lb)
Operation Temperature -10~45℃
Max. Humidity 85%【Non-condensing】
Physical Dimensions 205 x 114 x 175mm (W x H x D)

Analog Input and A/D Conversion

Analog Input and A/D Conversion
Type BDI-9301B
Input Sensitivity ≧0.4uV/D
ZERO Adjustment Range 0~24mV
Load Cell Excitation 12V±5%,280mA Remote Sensing.
Can Be connected up to eight 350Ω Load Cells.
Non-Linearity ±0.01% F.S
A/D Conversion Method ΔΣ
A/D Resolution ≒1/1,000,000
A/D Conversion Rate 40 times/sec
Max Load Cell Input Voltage 39mV
ZERO Temperature Comp ± (0.2uVvvv+0.001% of Dead Load) / ℃ typ
SPAN Temperature Comp ±0.001% / ℃ typ
Max Resolution 1/15,000